Software updates

Here you can find the latest software updates for our charging systems.
Simply select the product group of your devices to download the appropriate files.

Software update 5.22.3 for AMTRON® Professional(+)

Without calibration conformity

Please consider the following notes when updating the software to version 5.22.3:

When updating the software from version 4.61 (and lower) to version 5.22.3 via the web interface of the ECU, it is necessary to update the product to version 5.12.x first. For a software update via the backend system, this step is not necessary.

The update from 4.61 to 5.12.x can take up to 30 minutes. During the update, the bar "programming" in the web interface suddenly jumps to 100% after approx. 4 minutes. The controller is then no longer accessible for approx. 25 minutes and all LEDs are switched off. The update continues to run in the background. Do not switch off the wallbox during this time!

Software update 5.22.3 for AMEDIO® Professional(+)

With and without calibration conformity

For the current update 5.22.3 to your AMEDIO® Professional please contact our technical service:
emobility.support@mennekes.de

 

Please consider the following notes when updating the software to version 5.22.3:

When updating the software from version 4.61 (and lower) to version 5.22.3 via the web interface of the ECU, it is necessary to update the product to version 5.12.x first. For a software update via the backend system, this step is not necessary.

The update from 4.61 to 5.12.x can take up to 30 minutes. During the update, the bar "programming" in the web interface suddenly jumps to 100% after approx. 4 minutes. The controller is then no longer accessible for approx. 25 minutes and all LEDs are switched off. The update continues to run in the background. Do not switch off the wallbox during this time!

General documents software update 2.14

Software update 2.14 (TLS 1.0)

Software update 2.14 (including TLS 1.2)

To meet the increasing requirements for secure and encrypted communication to a backend system for the ACU, we also offer this update in combination with TLS 1.2 encryption. Due to the size of the software package, the software update of the operating system and the software of the MENNEKES ACU V4 (red housing) can only be performed on site via direct connection. A software update from the network or from the backend is not possible.

The link to download the software update package can be requested by e-mail: emobility.support@mennekes.de.

Please include the contact information with first name, last name as well as company name and company address.